Vapor Intrusion & Sub-Slab Depressurization

Vapor Intrusion Assessment & Sub-Slab Depressurization Design

Soil vapor, sub-slab, and indoor air sampling to evaluate vapor intrusion risk — and, when mitigation is needed, SSD system design and installation oversight that clears regulatory review and protects occupants.

What You Get

  • Soil vapor, sub-slab vapor, and indoor air sampling
  • Human health risk evaluation per OEHHA guidance
  • Custom SSD system design when mitigation is warranted
  • Post-mitigation performance sampling and verification
  • Regulatory coordination with DTSC and RWQCB
25+
Years Experience
1000s
Projects Completed
OEHHA
Guidance-Based Risk Review
CA PG
Licensed Oversight
Why It Matters

Vapor Intrusion Is an Occupant Health Issue and a Regulatory One

When a site has a history of chlorinated solvent or petroleum contamination — a former dry cleaner, a gas station, an industrial tenant — vapor intrusion into occupied buildings is one of the first things a regulator or buyer's environmental consultant will want evaluated. Getting the assessment wrong, or skipping it, is a liability problem that surfaces later, usually at the worst time.

We run vapor intrusion assessments that hold up to regulatory review — soil vapor, sub-slab, and indoor air sampling evaluated against OEHHA and DTSC/RWQCB screening levels — and if mitigation is warranted, we design sub-slab depressurization systems sized to the building and the contaminant, not an off-the-shelf template.

Post-installation, we verify the system is actually performing before we sign off, with sampling data to back it up.

How It Works

Assessment Through Mitigation

Every step scoped to the building, the contaminant, and the regulatory driver.

01

Assess

Soil vapor, sub-slab, and/or indoor air sampling to characterize vapor intrusion risk at the specific building.

02

Evaluate Risk

Results are compared against OEHHA and DTSC/RWQCB screening levels to determine whether mitigation is warranted.

03

Design & Install

If mitigation is needed, we design a site-specific SSD system and oversee installation and commissioning.

04

Verify

Post-mitigation sampling confirms the system is performing and supports regulatory sign-off.

Common Questions

Vapor Intrusion & SSD Questions We Hear Often

How do I know if my site needs a vapor intrusion assessment?

If there's a documented history of chlorinated solvents (PCE, TCE) or petroleum contamination on or near the property — especially a former dry cleaner, gas station, or industrial use — a regulator or buyer's consultant will likely require one.

What's the difference between assessment and mitigation?

Assessment (sampling and risk evaluation) tells you whether a problem exists. Mitigation (an SSD system) is the fix, installed only when the assessment shows it's warranted — we don't recommend a system you don't need.

How long does an SSD system take to design and install?

Design typically takes 1–2 weeks once sampling data is in hand; installation is usually completed in a few days depending on building size, with confirmation sampling shortly after.

Will this satisfy DTSC or RWQCB review?

Yes — assessments and mitigation designs are prepared to current OEHHA and DTSC/RWQCB guidance and documented for direct submission to the overseeing agency.

Need a Vapor Intrusion Assessment or SSD System?

Tell us about the site history and building use — we'll scope the right level of investigation.

Request a Consultation
Get In Touch

Request a Quote

Southern California Environmental Consulting

Serving Los Angeles, Orange County, San Diego, Riverside, Ventura, and all of Southern California. Most quotes turned around within 1 business day.

Send Us a Message